The pneumo-hydraulic multiplicators are used as source of pressure energy in hydraulic circuits. The maximum pressure is determined by the transmission ratio of pneumatic piston and piston rod. The piston return motion is obtained through a hydraulic circuit.
|
TYPE |
TRANSMISSION RATIO | DISPLACED OIL AMOUNT PER 10 mm OF STROKE |
MP 32 | 1:10 | 0,785 cm3 |
MP 40 | 1:6 | 2 cm3 |
MP 40 | 1:16 | 0,785 cm3 |
MP 50 | 1:10 | 2 cm3 |
MP 50 | 1:25 | 0,785 cm3 |
MP 63 | 1:10 | 3,14 cm3 |
MP 63 | 1:15 | 2 cm3 |
MP 80 | 1:16 | 3,14 cm3 |
MP 80 | 1:25 | 2 cm3 |
MP 100 | 1:16 | 4,9 cm3 |
MP 100 | 1:25 | 3,14 cm3 |
MP 125 | 1:15 | 8 cm3 |
MP 125 | 1:25 | 4,9 cm3 |
MP 160 | 1:16 | 12,5 cm3 |
MP 160 | 1:25 | 8 cm3 |
MP 200 | 1:25 | 12,5 cm3 |
« Back | Whole Page | Top ^ |